0x1Based on DAMOS13Aaron Sommer0Ignition MapRPM1664ms162385Degrees20.0000001.0000001VE Map Part LoadWhen not under WOT. RPM16064MS162385Correction30.000000255.0000001Major RPMUsed in VE map, Ignition Map, WOT enrichment, Maximum retart while knocking, knock detection map, retard per knock event, knock fuel enrichment, dwell map, re-engage ignition advance, dynamic ignition retard, maximum duty cycle for boost solenoid, load limit while knocking
100160020.000000255.0000001WOT enrichment1001639420.000000255.0000001TPS Angle for WOT Detection100160420.000000255.0000001Maximum Duty Cycle for Boost SolenoidTPS165723RPM1664%20.000000255.0000001Intake Air Temperature Scaling of LDR166416191520.000000255.0000001Rear Cat Check (1)CDHSH Codeword Heater diagnostics behind cat - 0 = off00Idle Target Based on Coolant Temp(1)Keep this table the same as the number 2 table10016131520.000000255.0000001Idle Target Based on Coolant Temp(2)Keep this table the same as the number 1 table10016131520.000000255.0000001Start Basic Injection Quantity10016131520.000000255.0000001Dwell Map NTBDThe voltage axis is not correct.166416663220.000000255.0000001Injection Start Angle162385166420.000000255.0000001Injector ConstantDivide old injector size by new injector size and multiply this constant by the ratio. You may have to play with this number a bit to get your car idling perfectly at 14.7.
300Rear Cat Check (2)CDKAT Codeword Catalyst-diagnose in OBDII-Mode - 0 = disable00Rear Cat Check (3)CDLSH Codeword probe behind catalytic converter in OBDII diagnostic mode. 0 = disable00RPM Limit (Soft)04Reset Speed of RPM LimitWhen RPM limit is reached, what level the RPM must drop to before the limiters are stopped.00Hysterisis for RPM Limit00Injector Voltage CorrectionOpening time in ms based on voltage.1001603220.000000255.0000001Boost Map - Requested Pressure RatioThis is the requested load function. More requested load = more boost.1600160020.000000255.0000001Speed Limit (hard) km/hFuel cut for maximum speed.56Injectory LatencyMinimum time it takes for the injector to open. I believe this number is tacked onto the values in the battery voltage correction table.085Configbyte for Gear Dependent Boost Control0 to disable00Idle IgnitionLeerlauf/Schub - Zündwinkel
Idle / push - ignition 10016131520.000000255.0000001Target Fuel Regeneration RateI have no idea what this table does. I included it because it varies between compared .bin files. 166416238520.000000255.0000001Constant for Consumption DisplayInjector flow in ml/sec. Multiply injector size in CC by 1.05 and divide by 60.
300RPM Limit (Hard)00RPM Limit (Hard) 2 00RPM Limit (Soft) 20x1F28300Speed Limit (soft) km/h06Load Limit when Knocking100160420.000000255.0000001RPM for Diagnosis of OverboostSet this to max for no limit00Maximum Retard while Knocking100166420.000000255.0000001Accleration Enrichment (DK)8648151520.000000255.0000001Knock Detection Map166416238520.000000255.0000001Retard Per Knock Event100166420.000000255.0000001Accleration Enrichment (K+L)8648131520.000000255.0000001Overcharge - LoadSet this to maximum to disable limits.
RPM axis is not internally linked.10086420.000000255.0000001Trips Required for Readiness00Ignition Retard for Catalytic Heating at Idledelta Zündwinkel für Kat-Heizung im Leerlauf 100RPM166420.000000255.0000001Re-engage Ignition AdvanceRPM1664C°16151520.000000255.0000001Dynamic Ignition RetardRPM1664Load16238520.000000255.0000001Engine Temperature Threshold for Knock ControlAt what engine temperature does the engine listen for knock.1515Knock Fuel Enrichment (1)ms162385RPM166420.000000255.0000001Knock Fuel Enrichment (2)ms162385RPM166420.000000255.0000001Idle Increase During Catlytic Converter Heating1600C°16151520.000000255.0000001Number of Ignitions After Which to Stop Catalytic Heating00Major LoadUsed in ignition map, knock fuel enrichment, knock detection map100160030.000000255.0000001Load (2)100160020.000000255.0000001Load (3)100160020.000000255.0000001Checksum Plugin by Simply Volvo9a53f577-d1c9-40c6-8691-7a54fa789d3a0x00x00x00x0error -> lamp: tank venting system fine leak0 to disable, 1 to enable1.00000000error -> lamp: tank venting system gross leak00error -> lamp: tank venting system00error -> lamp: shut-off valve active carbon filter (function)00error -> lamp: shut-off valve active carbon filter (output stage)00error -> lamp: tank venting valve00error -> lamp: tank pressure sensor00error -> lamp: secondary air system00error -> lamp: secondary air pump00error -> lamp: secondary air valve00error -> lamp: secondary air pump (output stage)00error -> lamp: secondary air valve (output stage)00codeword tester: secondary air system00codeword tester: secondary air pump00codeword tester: secondary air valve00codeword tester: secondary air pump (output stage)00codeword tester: secondary air valve (output stage)00diagnostics disable: tank pressure sensorCodeword Tank pressure sensor - diagnose shut-off (EURO-coding) - 0 diasbles pressure sensor diagnostic00diagnostics disable: tank venting systemCodeword tank vent diagnosis off (EURO-coding) - 0 disables tank vent system diagnosis00diagnostics disable: secondary air systemEuro-Byte for Diagnose Secondary Air System - 0 disables SAS diagnostics00diagnostics disable: ambient pressure (barometric) sensorCodeword for diagnosis ambient pressure sensor - 0 to disable ambient pressure (barometric) sensor diag00diagnostics disable: misfire detection0 should disable entire misfire detection diagnostic (default for european vehicles)00diagnostics disable: secondary air valve/pumpEuro-Byte for Diagnose output stage Secondary air valve/pump - 0 to disable the diagnostic00diagnostics disable: accelerometerCodeword DSWE shut-off (EURO-coding) -- Disables the accelerometer (acceleration sensor) used to detect rough roads. Part of misfire diagosis. 0 to disable this diagnostic.00diagnostics disable: intake air temperature sensorCodeword for diagnosis intake air temperature sensor - set to 0 to disable diagnostic00diagnostics replacement value: intake air temperatureWhen intake air temperature sensor diagnostic is disabled, this is the replacement value: set to DegreesCelcius+80 (IE: 100 = 20°C)00